3 rated data, 1 overview, Overview – Lenze 9400 Manual User Manual

Page 163: Multi-axis controllers

Advertising
background image

Multi-axis controllers

Rated data

Overview

5

163

EDS94SPP101 EN 7.1

5.3

Rated data

The E94AMxExxx4 devices can be used in the voltage range of 260 ... 775 V DC.

Note!

To ensure a faultless operation of the devices the code C00173 must be set

according to the mains voltage connected.

Emergency operation

Operation of the E94ASxxxx4 devices with an emergency voltage supply at +UG, -UG, is

possible from U

DC

260 V. The settings in C00173 and C00174 are to be adapted

accordingly.
Operation of the E94AMxxxx4 devices with an emergency voltage supply at +UG, -UG, is

possible with U

DC

260 V. The settings in C00173 and C00174 are to be adapted

accordingly. A 24-V supply at X2 is required.

5.3.1

Overview

Input data

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94AMxE0024

325/565/705

0 ( DC)

2.6/2.6/2.3

2.0/2.0/1.7

2

E94AMxE0034

325/565/705

0 ( DC)

4.3/4.3/3.8

3.2/3.2/2.9

2

E94AMxE0044

325/565/705

0 ( DC)

6.7/6.7/5.9

5.0/5.0/4.4

2

E94AMxE0074

325/565/705

0 ( DC)

12.1/12.1/10.6

9.1/9.1/8.0

2

E94AMxE0094

325/565/705

0 ( DC)

15.4/15.4/13.5

11.6/11.6/10.1

2

E94AMxE0134

325/565/705

0 ( DC)

20.6/20.6/18.0

15.5/15.5/13.5

2

E94AMxE0174

325/565/705

0 ( DC)

25.7/25.7/22.5

19.3/19.3/16.9

2

E94AMxE0244

325/565/705

0 ( DC)

35.5/35.5/31.1

26.3/26.3/23.3

2

E94AMxE0324

325/565/705

0 ( DC)

48.0/48.0/38.9

36.0/36.0/29.1

2

c

Temperature in the control cabinet