Single-axis controllers – Lenze 9400 Manual User Manual

Page 136

Advertising
background image

Single-axis controllers

Wiring

Devices in the range 145 ... 695 A (75 ... 370 kW)

4

136

EDS94SPP101 EN 7.1

Mains

Terminal X100

Marking

Description

Connection with ring

cable lug for M10

L1

L2

L3

Connection of the mains phases

SSP94KL801

Connection for the PE conductor on the supply side

Terminal data

Max. conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Device size 10:

E94ASxE4604

E94ASxE5724

E94ASxE6354

E94ASxE6954

2 x 400

3 x 150

2 x 750 mcm

3 x 350 mcm

19

168

WAF 16

Motor temperature monitoring

Terminal X106

Labelling

Description

T1

T2

Motor temperature monitoring with PTC element (type-A sensor,

switching performance according to EN 60947-8 for type-A tripping units)

or thermostat (NC contact).

SSP94X6106

Terminal data

Max. conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

2.5

12

0.5 ... 0.6

4.5 ... 6.2

Slot

0.6 x 3.5

With wire end ferrule

Advertising