Example 2 - single-axis controller with multi axes

Assumptions:

ƒ

400 V, 3 AC/PE

ƒ

4 axes in 3 power categories

ƒ

no particular dynamic performance requirements

The following motors (Mx) are selected:

Motor type

Rated power

Efficiency

Rated current

Index

[kW]

[A]

M1

MCS19P30

10.0

0.93

19

M2

MCS14H15

2.5

0.92

6.6

M3 ... M4

MCS09F38

1.2

0.90

2.5

For the above motor data, the following controllers (Gx) are selected:

Controller

Rated power

Typical motor

power

Power loss P

l

Rated current

Index

[kW]

[kW]

[kW]

[A]

G1

E94ASxE0244

16.3

11.0

0.50

23.5

G2

E94AMxE0074

4.8

3.0

0.19

7.0

G3 ... G4

E94AMxE0034

1.7

0.75

0.12

2.5

The power required by the drive system is determined with the below formula ( 8.5.5):
P

DCtotal

=(10 kW/0.93+0.50 kW)+ (2.5 kW/ 0.92+ 0.19 kW)+ 2*(1.2 kW /0.90 +0.12 kW)

P

DCtotal

= 17.1 kW

The calculated power requirement is used to select the single-axis controller with mains

choke:

Controller (+ mains choke)

Rated power (P

DC100%

)

Index

[kW]

(G1)

E94ASxE0244

+ E94AZMS0314

18.8

Note: Only the controller with mains choke reaches the required power.

Checking the power efficiency:
With 18.8 kW > 17.1 kW, P

DC100%

> P

DCtotal

.

Select cables and fuses in accordance with the Technical data.

G 1

G x

...

M

M

M

L2

L1

L3

3

AC

M

Fig. 8-5

Basic circuit diagram

Advertising