Accessories (overview), Filters rfi filters for single-axis controllers, Rated data – Lenze 9400 Manual User Manual
Page 523
Accessories (overview)
Filters
RFI filters for single-axis controllers
9
522
EDS94SPP101 EN 7.1
Rated data
Basis of the data
Mains
Voltage
Voltage range
Frequency range
U
LN
[V]
U
LN
[V]
f [Hz]
3/PE AC
230
180 - 0 % ... 264 + 0 %
45 ... 65
3/PE AC
400
320 - 0 % ... 440 + 0 %
45 ... 65
3/PE AC
500
400 - 0 % ... 550 + 0 %
45 ... 65
Voltage
Frequency
Current [A]
Number of
phases
[V]
[Hz]
max. +45 °C c
max. +55 °C c
E94AZMS0044
230/400/500
50/60
3.5/3.5/3.5
2.2/2.2/2.2
3
E94AZMS0104
230/400/500
50/60
10/10/10
6.2/6.2/6.2
3
E94AZMS0294
230/400/500
50/60
29/29/29
18/18/18
3
E94AZRS0544
230/400/500
50/60
54.0/54.0/54.0
40.5/40.5/40.5
3
E94AZRS0954
230/400/500
50/60
95.0/95.0/95.0
71.0/71.0/71.0
3
c
Temperature in the control cabinet
Power loss
Inductance
Voltage drop
P
loss
[W]
L [mH]
Δ
U [V]
E94AZMS0044
4
-
-
E94AZMS0104
8
-
-
E94AZMS0294
22
-
-
E94AZRS0544
50
–
–
E94AZRS0954
70
–
–