DC-bus operation
Rated data
DC-power requirements
8
324
EDS94SPP101 EN 7.1
Power loss P
V
[W]
Type
U
Lr
= 230 V
U
Lr
= 400 V
U
Lr
= 500 V
when controller is inhibited
Multi Drives
E94AMxE0024
65
80
95
40
E94AMxE0034
75
95
110
E94AMxE0044
90
120
130
E94AMxE0074
105
145
170
E94AMxE0094
130
170
205
E94AMxE0134
160
215
255
E94AMxE0174
185
255
300
E94AMxE0244
235
320
385
E94AMxE0324
290
405
490
Single Drives
E94ASxE0024
70
90
105
40
E94ASxE0034
85
105
125
E94ASxE0044
100
130
150
E94ASxE0074
125
160
190
E94ASxE0134
200
260
300
E94ASxE0174
240
300
350
E94ASxE0244
310
400
460
E94ASxE0324
750
750
750
75
E94ASxE0474
1050
1050
1050
E94ASxE0594
1100
1100
1100
E94ASxE0864
1500
1500
1500
100
E94ASxE1044
1800
1800
1800
E94ASxE1454
-
2100
2100
50
E94ASxE1724
-
2200
2200
50
E94ASxE2024
-
2600
2600
E94ASxE2454
-
3300
3300
50
E94ASxE2924
-
4100
4100
E94ASxE3664
-
4900
4900
E94ASxE4604
-
6200
6200
100
E94ASxE5724
-
7200
7200
E94ASxE6354
-
7700
7700
E94ASxE6954
-
8700
8700