Multi-axis controllers, Rated data overcurrent operation, 500 v – Lenze 9400 Manual User Manual
Page 172
Multi-axis controllers
Rated data
Overcurrent operation
5
172
EDS94SPP101 EN 7.1
500 V
Type
I [A] in a cycle of 5 seconds c
f = 2 kHz
f = 4 kHz
f = 8 kHz
f = 16 kHz
E94AMxE0024
6.0
1.4
6.0
1.4
4.2
1.0
-
-
E94AMxE0034
10.0
2.3
10.0
2.3
7.0
1.6
-
-
E94AMxE0044
16.0
3.8
16.0
3.8
11.2
2.6
-
-
E94AMxE0074
21.0
6.6
21.0
6.6
14.7
4.6
-
-
E94AMxE0094
27.9
8.7
27.9
8.7
19.5
6.1
-
-
E94AMxE0134
39.0
12.2
39.0
12.2
27.3
8.5
-
-
E94AMxE0174
49.5
15.5
49.5
15.5
34.7
10.8
-
-
E94AMxE0244
70.5
22.0
70.5
22.0
41.1
15.4
-
-
E94AMxE0324
76.8
30.0
76.8
30.0
62.2
19.4
-
-
500 V
Type
I [A] in a cycle of 3 minutes d
f = 2 kHz
f = 4 kHz
f = 8 kHz
f = 16 kHz
E94AMxE0024
2.8
1.4
2.8
1.4
2.0
1.0
-
-
E94AMxE0034
4.7
2.4
4.7
2.4
3.3
1.6
-
-
E94AMxE0044
7.5
3.8
7.5
3.8
5.3
2.6
-
-
E94AMxE0074
13.2
6.6
13.2
6.6
9.2
4.6
-
-
E94AMxE0094
17.5
8.7
17.5
8.7
12.2
6.1
-
-
E94AMxE0134
24.4
12.2
24.4
12.2
17.1
8.5
-
-
E94AMxE0174
31.0
15.5
31.0
15.5
21.7
10.8
-
-
E94AMxE0244
44.2
22.1
44.2
22.1
30.8
15.4
-
-
E94AMxE0324
60.0
30.0
60.0
30.0
38.9
19.4
-
-