Single-axis controllers
Rated data (devices for 400/500V mains)
Overcurrent operation
4
70
EDS94SPP101 EN 7.1
230 V
Type
I [A] in a cycle of 3 minutes d
f = 2 kHz
f = 4 kHz
f = 8 kHz
f = 16 kHz
E94ASxE0024
2.8
1.4
2.8
1.4
2.3
1.1
-
-
E94ASxE0034
4.7
2.4
4.7
2.4
3.8
1.9
-
-
E94ASxE0044
7.5
3.8
7.5
3.8
6.0
3.0
-
-
E94ASxE0074
13.2
6.6
13.2
6.6
10.5
5.3
-
-
E94ASxE0134
24.4
12.2
24.4
12.2
19.5
9.8
-
-
E94ASxE0174
31.0
15.5
31.0
15.5
24.8
12.4
-
-
E94ASxE0244
44.2
22.1
44.2
22.1
35.3
17.6
-
-
E94ASxE0324
57.6
28.8
57.6
28.8
48.0
24.0
-
-
E94ASxE0474
70.5
35.3
70.5
35.3
61.6
30.6
-
-
E94ASxE0594
88.5
44.3
88.5
44.3
61.4
30.7
-
-
E94ASxE0864
129
64.5
129
64.5
109
55.0
-
-
E94ASxE1044
156
78.0
156
78.0
118
58.2
-
-
E94ASxE1454
218
109
218
109
164
81.2
-
-
E94ASxE1724
258
129
258
129
194
96.3
-
-
E94ASxE2024
303
152
303
152
228
113
-
-
E94ASxE2454
368
184
314
157
240
120
-
-
E94ASxE2924
438
219
374
187
286
143
-
-
E94ASxE3664
549
275
468
234
359
179
-
-
E94ASxE4604
690
345
552
276
391
193
-
-
E94ASxE5724
858
429
686
343
429
217
-
-
E94ASxE6354
953
476
762
381
476
241
-
-
E94ASxE6954
1043
521
834
417
521
264
-
-