Single-axis controllers, Rated data for internal brake chopper, Within a cycle time t – Lenze 9400 Manual User Manual

Page 65

Advertising
background image

Single-axis controllers

Rated data (devices for 400/500V mains)

Operation at rated mains voltage 500 V

4

65

EDS94SPP101 EN 7.1

Rated data for internal brake chopper

R

Bmin

[Ω]

I

BRmax

[A]

P

BRmax

[kW]

I

BRd

[A]

P

Bd

[kW]

t

Z

[s]

t

on

[s]

t

fp

[s]

Type
E94ASxE0024

82

9.6

7.6

4.3

1.5

5

0.7

1.1

E94ASxE0034

82

9.6

7.6

4.3

1.5

5

0.7

1.1

E94ASxE0044

47

16.8

13.3

6.9

2.3

5

0.6

1.0

E94ASxE0074

47

16.8

13.3

8.1

3.1

5

0.8

1.0

E94ASxE0134

27

29.3

23.1

14.4

5.5

5

0.8

1.2

E94ASxE0174

18

43.9

34.7

20.6

7.6

5

0.7

1.1

E94ASxE0244

18

43.9

34.7

24.8

11.1

5

1.1

1.6

E94ASxE0324

18.0

43.9

34.7

28.9

15.0

600

260

600

E94ASxE0474

15.0

52.7

41.6

38.4

22.0

600

320

600

E94ASxE0594

15.0

52.7

41.6

44.8

30.0

600

430

600

E94ASxE0864

7.5

105.3

83.2

77.5

45.0

600

320

600

E94ASxE1044

7.5

105.3

83.2

85.7

55.0

600

400

600

E94ASxE1454

5.0

158

125

87

37.4

600

60

62

E94ASxE1724

4.3

184

145

101

43.5

600

60

62

E94ASxE2024

3.5

226

178

124

53.5

600

60

62

E94ASxE2454

2.8

282

223

154

66.9

600

60

62

E94ASxE2924

2.3

343

271

188

81.4

600

60

62

E94ASxE3664

1.8

451

357

247

107

600

60

62

E94ASxE4604

1.4

564

446

289

117

300

30

33

E94ASxE5724

1.2

658

520

312

117

300

28

32

E94ASxE6354

1.1

718

567

327

117

300

25

29

E94ASxE6954

1.1

718

567

327

117

300

25

29

R

Bmin

Minimum brake resistance, nominal value ±10 %

I

BRmax

Peak current

P

BRmax

Peak braking power

I

BRd

Continuous current RMS - important for the dimensioning of the cables

P

Bd

Continuous braking power

t

Z

Cycle time, periodic load change with running time and recovery time

t

on

Running time

t

Z

- t

on

Recovery time

t

fp

Maximum running time without initial load and compliance with the recovery

time

Note on the brake chopper data
The brake chopper can output the peak braking power maximally for the specified time t

on

within a cycle time t

Z

.

The brake chopper can output the peak braking power from unloaded states once for the

time t

fp

, e. g. after mains connection or after a recovery time of > 5 x t

Z

.

If the times are exceeded, the brake chopper is clocked so that only the continuous braking

power is output. This serves to the protection of the brake chopper, however, it does not

protect the brake resistor. The brake resistor connected can be protected separately by

parameterisation (C00129 ... C00133) or a thermal contact.
Further information can be found in the software manual.