4

92

EDS94SPP101 EN 7.1

4.5

Mechanical installation

4.5.1

Important notes

Note!

The devices must be installed in housings (e.g. control cabinets) to meet

applicable regulations.

4.5.2

Devices in the range 2 ... 24 A (0.37 ... 11 kW)

Proceed as follows for the installation:
1. Prepare M5 threaded holes on the mounting plate according to the mounting grid.
2. When using footprint filters: Screw installation backplane and footprint filter

together.
– Use screw and washer assemblies M5 x 20 mm or hexagon socket screws

M5 x 20 mm with washers.

– Tightening torque: 3.4 Nm (30 lb-in)

3. Screw the installation backplane or footprint filter with installation backplane onto

the mounting plate. Do not yet tighten the screws.
– Use M5 screw and washer assemblies or M5 hexagon socket screws with washers.
– The screw joint in the installation backplane may jut out no more than 7 mm.

4. Repeat steps 2 and 3 with further installation backplanes which are mounted side by

side.

5. Align all installation backplanes.
6. Screw all installation backplanes/footprint filters onto the mounting plate.

– Tightening torque: 3.4 Nm (30 lb-in).