3 operation at a rated mains voltage of 500 v, Operation at a rated mains voltage of 500 v, Power supply modules – Lenze 9400 Manual User Manual

Page 223: Input data, Output data

Advertising
background image

Power supply modules

Rated data (devices for 400/500V mains)

Operation at a rated mains voltage of 500 V

6

223

EDS94SPP101 EN 7.1

6.3.3

Operation at a rated mains voltage of 500 V

Basis of the data
Mains

Voltage

Voltage range

Frequency range

U

LN

[V]

U

LN

[V]

f [Hz]

3/PE AC

500

400 - 0 % ... 550 + 0 %

45 - 0 % ... 65 + 0 %

Input data

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94APNE0104

500

50/60

8

6

3

E94APNE0364

500

50/60

29

21.8

3

E94APNE1004

500

50/60

82

61

3

E94APNE2454

500

50/60

200

150

3

c

Temperature in the control cabinet

Voltage

Continuous input power

Type

[V]

S

L

[kVA]

E94APNE0104

500

6.9

E94APNE0364

500

25.1

E94APNE1004

500

70.9

E94APNE2454

500

173

Output data

Basis of the data
Mains

Voltage

U

DC

[V]

Voltage range

U

DC

[V]

Frequency range

f [Hz]

2/PE DC

705

565 - 0 % ... 775 + 0 %

-

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94APNE0104

705

0 (DC)

10

7.5

2

E94APNE0364

705

0 (DC)

36

27

2

E94APNE1004

705

0 (DC)

100

75

2

E94APNE2454

705

0 (DC)

245

184

2

c

Temperature in the control cabinet