2 devices for 400/ 500v-mains, Devices for 400/500v-mains, Multi-axis controllers – Lenze 9400 Manual User Manual

Page 165: Mains

Advertising
background image

Multi-axis controllers

Rated data

Devices for 400/500V-mains

5

165

EDS94SPP101 EN 7.1

5.3.2

Devices for 400/500V-mains

5.3.2.1

Operation on 230 V

AC

mains

Basis of the data
Mains

Voltage

U

DC

[V]

Voltage range

U

DC

[V]

Frequency range

f [Hz]

2/PE DC

325

260 - 0 % ... 370 + 0 %

-

Input current at I

aN8

Output power

Motor power

(typical)

(without external mains

choke)

8 kHz, U, V, W

8 kHz, 4 pol. ASM

Type

I

DC

[A]

S

aN8

[kVA]

P

aN

[kW]

P

aN

[hp]

E94AMxE0024

2.6

0.6

0.18

0.25

E94AMxE0034

4.3

1.0

0.37

0.5

E94AMxE0044

6.7

1.6

0.75

1

E94AMxE0074

12.1

2.8

1.5

2

E94AMxE0094

15.4

3.7

2.2

3

E94AMxE0134

20.6

5.2

3

4

E94AMxE0174

25.7

6.6

4

5.5

E94AMxE0244

35.5

9.4

5

7.5

Output currents [A] at switching frequency

2 kHz

4 kHz

8 kHz

16 kHz

4)

Type

I

aN2

I

aM2

I

aN4

I

aM4

I

aN8

I

aM8

I

aN16

E94AMxE0024

1.9

6.0

1.9

6.0

1.5

4.8

1.1

E94AMxE0034

3.1

10.0

3.1

10.0

2.5

8.0

1.9

E94AMxE0044

5.0

16.0

5.0

16.0

4.0

12.8

3.0

E94AMxE0074

8.8

21.0

8.8

21.0

7.0

16.8

5.3

E94AMxE0094

11.7

28.0

11.7

28.0

9.3

22.4

7.0

E94AMxE0134

16.3

39.0

16.3

39.0

13.0

31.2

9.8

E94AMxE0174

20.6

49.5

20.6

49.5

16.5

39.6

12.4

E94AMxE0244

29.4

70.5

29.4

70.5

23.5

47.0

17.6

I

aN2

Rated value of permanent output current at a frequency of ≥ 0 Hz

I

aM2

Maximum output current (overload current) at frequency ≥ 0 Hz

z

Periodic load change of 0.5 s with I

aM2

and recovery time of 4.5 s with

75 % I

aN2

I

aN4

, I

aN8,

I

aN16

Rated value of continuous output current at a frequency of ≥ 5 Hz
(reduce to 0.66 * I

aNx

for 0 ... 5 Hz)

I

aM4

, I

aM8

Maximum output current (overload current) at frequency ≥ 5 Hz
(reduce to 0.66 * I

aMx

for 0 ... 5 Hz)

z

Periodic load change of 0.5 s with I

aMx

and recovery time of 4.5 s with

75 % I

aNx

z

Can be achieved using the setting ”x kHz fixed” in C00018

bold

Nominal value I

aN