Accessories (overview), Communication modules ethernet interface, Connections – Lenze 9400 Manual User Manual

Page 359: Displays

Advertising
background image

Accessories (overview)

Communication modules

Ethernet interface

9

359

EDS94SPP101 EN 7.1

Connections

Pos.

Description

X250

Connection to the external supply of the communication module

Design: plug connector with screw connection, 2-pole

X251

Connection for ETHERNET Powerlink

Design: RJ45 socket in accordance with IEC 60603-7, with integrated LEDs

X252

Displays

LED

Description

Pos.

Colour

Condition

MS

Green

Blinking

Communication module is supplied with voltage, but has no connection to the standard device

(standard device is either switched off, in the initialisation phase, or not available).

On

Communication module is supplied with voltage and has a connection to the standard device.

ME

Red

On

There is an error in the area of the communication module.

BS

Green

The LED functions are controlled by the NMT state machine.
Off

EPL network is not active

(LED off)

EPL status:

NMT_GS_OFF, NMT_GS_INITIALISATION,

NMT_CS_NOT_ACTIVE / NMT_MS_NOT_ACTIVE
EPL network in the initialisation phase.

(LED flashes once within a second)

EPL status:

NMT_CS_PREOPERATIONAL_1 / NMT_MS_PREOPERATIONAL_1
EPL in the initialisation phase with cyclic traffic.

(LED flashes twice within a second)

EPL status:

NMT_CS_PREOPERATIONAL_2 / NMT_MS_PREOPERATIONAL_2
EPL node waits for the starting signal.

(LED flashes three times within a second)

EPL status:

NMT_CS_READY_TO_OPERATE / NMT_MS_READY_TO_OPERATE
EPL node has not found any EPL master and is in the ”BASIC-Ethernet” operating mode.

(LED is blinking at a frequency of 10 Hz)

EPL status:

NMT_CS_BASIC_ETHERNET
EPL node in the ”Stopped” status. Waiting for disconnection.

(LED is blinking at a frequency of 2.5 Hz)

EPL status:

NMT_CS_STOPPED
EPL node in the operating phase

(LED is on continuously)

EPL status:

NMT_CS_OPERATIONAL / NMT_MS_OPERATIONAL

BE

Red

Off

There is no error.

On

There is an error.

DE

Red

On

The communication module is not accepted by the standard device (see notes given in the

documentation on the standard device).

Signalling at the terminals X211 or X212:
-

Red

On

Ethernet collision is available.

-

Green

On

Ethernet connection is available.

Blinking

Ethernet connection with active data communication