Single-axis controllers

General data and operating conditions

4

44

EDS94SPP101 EN 7.1

EMC
Operation on public supply

systems

EN 61800-3

The controllers are designed for use in an industrial

environment. Operation on public networks requires

measures to be taken for limiting the expected emission of

radio interferences.

Noise emission, in cables

Design

”Single Drive”

EN 61800-3

see Tab. 4-2 EMC protection requirements

Design

”Multi Drive”

Depending on the filter at the central DC supply module.

Noise immunity (to EN 61800-3)

Electrostatic discharge

(ESD)

EN 61000-4-2

8 kV with air discharge,

4 kV with contact discharge against housing

Radio frequency

Cable-guided

EN 61000-4-6

150 kHz ... 80 MHz, 10 V 80 % AM (1 kHz)

Interference (housing) EN 61000-4-3

80 MHz ... 1000 MHz, 10 V/m 80 % AM (1 kHz)

Burst

Power terminals and

interfaces

EN 61000-4-4

2 kV/5 kHz

Signal interfaces

EN 61000-4-4

1 kV/5 kHz

Control connections

EN 61000-4-4

2 kV/5 kHz

Surge (surge voltage)

Power terminals

EN 61000-4-5

1.2/50 μs,

1 kV phase/phase, 2 kV phase/PE

Advertising