Single-axis controllers – Lenze 9400 Manual User Manual
Page 44
Single-axis controllers
General data and operating conditions
4
44
EDS94SPP101 EN 7.1
EMC
Operation on public supply
systems
EN 61800-3
The controllers are designed for use in an industrial
environment. Operation on public networks requires
measures to be taken for limiting the expected emission of
radio interferences.
Noise emission, in cables
Design
”Single Drive”
EN 61800-3
see Tab. 4-2 EMC protection requirements
Design
”Multi Drive”
Depending on the filter at the central DC supply module.
Noise immunity (to EN 61800-3)
Electrostatic discharge
(ESD)
EN 61000-4-2
8 kV with air discharge,
4 kV with contact discharge against housing
Radio frequency
Cable-guided
EN 61000-4-6
150 kHz ... 80 MHz, 10 V 80 % AM (1 kHz)
Interference (housing) EN 61000-4-3
80 MHz ... 1000 MHz, 10 V/m 80 % AM (1 kHz)
Burst
Power terminals and
interfaces
EN 61000-4-4
2 kV/5 kHz
Signal interfaces
EN 61000-4-4
1 kV/5 kHz
Control connections
EN 61000-4-4
2 kV/5 kHz
Surge (surge voltage)
Power terminals
EN 61000-4-5
1.2/50 μs,
1 kV phase/phase, 2 kV phase/PE