Rated data (devices for 400/500V mains)

Mains filters for regenerative power supply modules

7

280

EDS94SPP101-7.1

With different motor cable lengths, per axis at least 25 % of the longest cable must be

considered when calculating the total motor cable length.

Example: 1

Motor cable length l

mot

[m]

Axis

Actual

value

min. 25 % of the longest cable

To be considered

1

6

0.25 * 20 = 5

6

2 ... 4

3 * 10

3 * 10

5

20

Õ

20

Total

56

max. permissible for 5 axes: ∑< 60

56

EMC class C2 will be complied with.

;

Example: 2

Motor cable length l

mot

[m]

Axis

Actual

value

min. 25 % of the longest cable

To be considered

1 ... 4

4 * 5

0.25 * 40 = 10

4 * 10

5

40

Õ

20

Total

60

max. permissible for 5 axes: ∑< 60

80

EMC class C2 will not be complied with.

:

Example: 3

Motor cable length l

mot

[m]

Axis

Actual

value

min. 25 % of the longest cable

To be considered

1 ... 3

3 * 100 Õ

0.25 * 100 = 25

3 * 100

4

50

50

5 ... 10

6 * 15

6 * 25

Total

410

max. permissible for 10 axes: ∑ < 500

500

EMC class C2 will be complied with.

;

Example: 4

Motor cable length l

mot

[m]

Axis

Actual

value

min. 25 % of the longest cable

To be considered

1 ... 4

4 * 100 Õ

0.25 * 100 = 25

4 * 100

5 ... 10

6 * 15

6 * 25

Total

490

max. permissible for 10 axes: ∑ < 500

550

EMC class C2 will not be complied with.

: