3 rated data ( devices for 400/ 500v mains), 1 overview, 3 rated data (devices for 400/500v mains) – Lenze 9400 Manual User Manual

Page 47: Overview, Single-axis controllers

Advertising
background image

Single-axis controllers

Rated data (devices for 400/500V mains)

Overview

4

47

EDS94SPP101 EN 7.1

4.3

Rated data (devices for 400/500V mains)

The E94ASxExxx4 devices can be used in the voltage range of 180 V ... 550 V AC.

Note!

To ensure a faultless operation of the devices the code C00173 must be set

according to the mains voltage connected.

Emergency operation

Operation of the E94ASxxxx4 devices with an emergency voltage supply at +UG, -UG, is

possible from U

DC

260 V. The settings in C00173 and C00174 are to be adapted

accordingly.
Operation of the E94AMxxxx4 devices with an emergency voltage supply at +UG, -UG, is

possible with U

DC

260 V. The settings in C00173 and C00174 are to be adapted

accordingly. A 24-V supply at X2 is required.

4.3.1

Overview

Input data

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94ASxE0024

230/400/500

50/60

2.1/2.1/1.8

1.6/1.6/1.4

3

E94ASxE0034

230/400/500

50/60

3.5/3.5/3.1

2.6/2.6/2.3

3

E94ASxE0044

230/400/500

50/60

5.5/5.5/4.8

4.1/4.1/3.6

3

E94ASxE0074

230/400/500

50/60

9.9/9.9/8.6

7.4/7.4/6.5

3

E94ASxE0134

230/400/500

50/60

16.8/16.8/14.7

12.6/12.6/11.0

3

E94ASxE0174

230/400/500

50/60

21.0/21.0/18.3

15.8/15.8/13.8

3

E94ASxE0244

230/400/500

50/60

29.0/29.0/25.4

21.8/21.8/19.1

3

E94ASxE0324

230/400/500

50/60

29.0/29.0/26.0

22.0/22.0/20.0

3

E94ASxE0474

230/400/500

50/60

43.0/43.0/39.0

32.0/32.0/29.0

3

E94ASxE0594

230/400/500

50/60

54.0/54.0/47.0

40.5/40.5/35.3

3

E94ASxE0864

230/400/500

50/60

79.0/79.0/70.0

59.0/59.0/52.0

3

E94ASxE1044

230/400/500

50/60

95.0/95.0/84.0

71.0/71.0/63.0

3

E94ASxE1454

400/500

50/60

140/140

126/126

3

E94ASxE1724

400/500

50/60

166/166

149/149

3

E94ASxE2024

400/500

50/60

195/195

176/176

3

E94ASxE2454

400/500

50/60

237/237

213/213

3

E94ASxE2924

400/500

50/60

280/280

252/252

3

E94ASxE3664

400/500

50/60

354/354

319/319

3

E94ASxE4604

400/500

50/60

444/444

400/400

3

E94ASxE5724

400/500

50/60

553/553

498/498

3

E94ASxE6354

400/500

50/60

614/614

553/553

3

E94ASxE6954

400/500

50/60

672/672

605/605

3

c

Temperature in the control cabinet

Advertising