3 rated data ( devices for 400/ 500v mains), 3 rated data (devices for 400/500v mains), Regenerative power supply modules – Lenze 9400 Manual User Manual
Page 265
Regenerative power supply modules
Rated data (devices for 400/500V mains)
7
265
EDS94SPP101-7.1
7.3
Rated data (devices for 400/500V mains)
Note!
The operation of the regenerative power supply modules is only permissible
with an assigned mains filter.
Assignment of filters to standard devices
Mains filter
Regenerative power supply module
Device size
Standard device
Installation
backplane
E94AZMR0264SDB
E94AZMR0264LDB
E94ARNE0134
E94AZPP0364
GG3
E94AZMR0474SDB
E94AZMR0474LDB
E94ARNE0244
E94AZMR0xx
SD
B -> ”short distance”
E94AZMR0xx
LD
B -> ”long distance”
General data
Power loss P
V
[W]
Type
Total (when operating with I
aN
)
Constant (control electronics only)
E94ARNE0134
150
40
E94ARNE0244
230
40
Power loss
Inductance
Regenerative
inductance
Voltage drop
P
V
[W]
L [mH]
L
gen
[mH]
Δ
U [V]
E94AZMR0264SDB
65
0.77 ±10 %
0.84 ±10 %
6.3
E94AZMR0264LDB
72
E94AZMR0474SDB
85
0.42 ±10 %
1.54 ±10 %
6.2
E94AZMR0474LDB
101