Accessories (overview), Danger – Lenze 9400 Manual User Manual
Page 442
Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHN0025
9
442
EDS94SPP101 EN 7.1
Permissible operating frequencies
Recommended brake
Power
Coil: Voltage DC 205 V
Permissible operating frequency
Type
P [W]
L [H]
I [A] (20 °C)
[1/min]
BFK457-06E
BFK458-06E
20
76
0.10
60
BFK457-08E
BFK458-08E
25
66
0.12
60
BFK457-10E
BFK458-10E
30
85
0.15
60
BFK457-12E
BFK458-12E
40
107
0.20
40
BFK457-14E
BFK458-14E
50
102
0.24
30
BFK457-16E
BFK458-16E
55
127
0.27
20
BFK457-18E
BFK458-18E
85
100
0.41
10
BFK457-20E
BFK458-20E
100
115
0.49
8
BFK457-25E
BFK458-25E
110
134
0.54
6
Safety instructions
During installation the notes given in the documentation for the standard
device must be observed!
Danger!
Dangerous electrical voltage!
Dangerous electrical voltages may be applied to the connections of the brake
switch.
Possible consequences:
ƒ
Death or severe injuries when touching the terminals.
Protective measures:
ƒ
Disconnect the standard device and the brake switch from the mains before
carrying out any operations.
ƒ
Check that all power terminals are deenergised.