Accessories (overview), Danger – Lenze 9400 Manual User Manual

Page 442

Advertising
background image

Accessories (overview)

Motor holding brake control modules

Motor holding brake control module E94AZHN0025

9

442

EDS94SPP101 EN 7.1

Permissible operating frequencies

Recommended brake

Power

Coil: Voltage DC 205 V

Permissible operating frequency

Type

P [W]

L [H]

I [A] (20 °C)

[1/min]

BFK457-06E

BFK458-06E

20

76

0.10

60

BFK457-08E

BFK458-08E

25

66

0.12

60

BFK457-10E

BFK458-10E

30

85

0.15

60

BFK457-12E

BFK458-12E

40

107

0.20

40

BFK457-14E

BFK458-14E

50

102

0.24

30

BFK457-16E

BFK458-16E

55

127

0.27

20

BFK457-18E

BFK458-18E

85

100

0.41

10

BFK457-20E

BFK458-20E

100

115

0.49

8

BFK457-25E

BFK458-25E

110

134

0.54

6

Safety instructions

During installation the notes given in the documentation for the standard

device must be observed!

Danger!

Dangerous electrical voltage!
Dangerous electrical voltages may be applied to the connections of the brake

switch.
Possible consequences:

ƒ

Death or severe injuries when touching the terminals.

Protective measures:

ƒ

Disconnect the standard device and the brake switch from the mains before

carrying out any operations.

ƒ

Check that all power terminals are deenergised.

Advertising