Dc-bus operation – Lenze 9400 Manual User Manual

Page 332

Advertising
background image

DC-bus operation

Basic dimensioning

Filters

8

332

EDS94SPP101 EN 7.1

RFI filter

DC power supply module

Type

Device size

Type

Device size

E94AZRP0084

1

E94APNE0104

1

E94AZRP0294

1

E94APNE0364

3

E94AZRP0824

4

E94APNE1004

4

E94AZRP2004

4

E94APNE2454

5

The RFI filters are designed for the following conditions:

ƒ

6 interconnected devices,

ƒ

each with a 10 m motor cable,

ƒ

EMC category C2.

In applications with a different number of interconnected devices or different motor cable

lengths, the filters may have to be specially dimensioned.

Note!

To observe EMC category C2, measures must be carried out on the

device-internal EMC filters of the drive components in the network system.

The measures for the individual devices are described in the chapter ”Wiring”,

section ”Earthing of internal EMC filters”.

When using the mains filters assigned, conditions must be observed for compliance with

EMC class C2:

ƒ

The measures for the use on IT systems must be applied to all axis modules in the

interconnection (separation of internal filter components from PE).

ƒ

The maximum sum total of all motor cable lengths (Σ l

mot

) for the filter used must

be observed.

Advertising