Accessories (overview) – Lenze 9400 Manual User Manual

Page 414

Advertising
background image

Accessories (overview)

Safety modules

SM301

9

414

EDS94SPP101 EN 7.1

Technical data
The module and the safe output must be supplied with 24 V from safely separated power

supply units. To maintain electrical isolations, separate voltage supplies are required.

Detailed features of the 24-V supply
Terminal

Specification

[Unit]

min.

typ.

max.

+, -

Supply voltage of the module via a safely separated

power supply unit (SELV/PELV)

[V]

19.2

24

30

Input current

[mA]

350

24O, GO

Supply voltage of the safe output via a safely

separated power supply unit (SELV/PELV)

[V]

18

24

30

Input current

[mA]

1100

Functions

ƒ

Safe torque off (STO)
(formerly: Safe standstill, protection against unexpected start-up)

ƒ

Safe stop 1 (SS1)

ƒ

Safe stop 2 (SS2) - see SOS

ƒ

Safe stop emergency (SSE)

ƒ

Safe operational stop (SOS) - in accordance with EN 61800-5-2: SOS is designed with

speed monitoring

ƒ

Safe maximum speed (SMS)

ƒ

Safely limited speed 1 (SLS1)

ƒ

Safe operation mode selector (OMS)

ƒ

Safe enable switch (ES)

ƒ

Safe speed monitor (SSM)

ƒ

Safe monitor (output)

ƒ

Connection of safety sensors

ƒ

Safe parameterisation

ƒ

Safety bus connection (PROFIsafe V1)

Additional functions from SM301 V1.1

ƒ

Safely limited speed 2 (SLS2)

ƒ

Safely limited speed 3 (SLS3)

ƒ

Safely limited speed 4 (SLS4)

ƒ

Safe cascading (CAS) via SD-In4/SD-Out1

ƒ

Safety bus connection (PROFIsafe V2)

Advertising