Rated data (devices for 400/500V mains)

Operation at rated mains voltage 500 V

4

62

EDS94SPP101 EN 7.1

Output currents [A] at switching frequency

2 kHz

4 kHz

8 kHz

16 kHz

4)

Type

I

aN2

I

aM2

I

aN4

I

aM4

I

aN8

I

aM8

I

aN16

E94ASxE0024

1.9

3)

6.0

1.9

3)

6.0

1.3

4.2

1.0

E94ASxE0034

3.1

3)

10.0

3.1

3)

10.0

2.2

7.0

1.6

E94ASxE0044

5.0

3)

16.0

5.0

3)

16.0

3.5

11.2

2.6

E94ASxE0074

8.8

3)

21.0

8.8

3)

21.0

6.1

14.7

4.6

E94ASxE0134

16.3

3)

39.0

16.3

3)

39.0

11.4

27.3

8.5

E94ASxE0174

20.6

3)

49.5

20.6

3)

49.5

14.4

34.7

10.8

E94ASxE0244

29.4

3)

58.8

29.4

3)

58.8

20.6

41.1

15.4

4)

E94ASxE0324

38.4

76.8

33.6

67.2

28.0

64.0

16.8

E94ASxE0474

47.0

94.0

41.1

82.2

35.8

71.6

21.5

E94ASxE0594

59.0

118

51.6

103

35.9

71.8

21.5

E94ASxE0864

86.0

172

75.3

150

63.9

127

38.3

E94ASxE1044

104

208

91.0

182

68.3

136

40.9

E94ASxE1454

145

261

145

261

89

161

-

E94ASxE1724

172

310

172

310

105

189

-

E94ASxE2024

202

364

202

364

115

206

-

E94ASxE2454

245

441

209

376

140

252

-

E94ASxE2924

292

526

250

450

167

301

-

E94ASxE3664

366

659

313

563

210

378

-

E94ASxE4604

460

828

368

662

228

410

-

E94ASxE5724

572

1030

458

824

250

450

-

E94ASxE6354

635

1143

508

914

278

500

-

E94ASxE6954

695

1251

556

1001

305

549

-

I

aN2

Rated value of permanent output current at a frequency of ≥ 0 Hz

I

aM2

Maximum output current (overload current) at frequency ≥ 0 Hz
E94ASxE0024 ... E94ASxE1044:

z

Periodic load change of 0.5 s with I

aM2

and recovery time of 4.5 s with

75 % I

aN2

E94ASxE1454 ... E94ASxE6954:

z

Periodic load change of 10 s with I

aM2

and recovery time of 50 s with

75 % I

aN2

I

aN4

, I

aN8,

I

aN16

Rated value of continuous output current at a frequency of ≥ 5 Hz
(reduce to 0.66 * I

aNx

for 0 ... 5 Hz)

I

aM4

, I

aM8

Maximum output current (overload current) at frequency ≥ 5 Hz
(reduce to 0.66 * I

aMx

for 0 ... 5 Hz)

z

Can be achieved using the setting ”x kHz fixed” in C00018

E94ASxE0024 ... E94ASxE1044:

z

Periodic load change of 0.5 s with I

aMx

and recovery time of 4.5 s with

75 % I

aNx

E94ASxE1454 ... E94ASxE6954:

z

Periodic load change of 10 s with I

aM2

and recovery time of 50 s with

75 % I

aN2

bold

Nominal value I

aN

3)

Operation with permanent currents > I

aN8

requires an external mains choke.

4)

Temperature inside the control cabinet = +35 ... +55 °C: 2.5 %/K current

derating