Accessories (overview)

Function modules

Digital frequency

9

395

EDS94SPP101 EN 7.1

Assignment of the Sub-D plug connector

Stop!

The output voltages on X9/4 and on X10/4 may not be interconnected. This

applies to both the wiring of several modules and to the wiring of one module

(e. g. for purposes of simulation).
Use system cables not connecting pin 4 for this applications only.

Tip!

We recommend the use of Lenze system cables. For this purpose, please read

the documentation for the basic device.

X9

Pin

Designation

Explanation

1

6

5

9

1

B

TTL input signal by encoder or encoder simulation

2

A

3

A

4

+5 V

Regulated voltage supply for encoder

(pin 8 = sense must be used, max. control range 5 ... 9 V)

5

GND

-

6

Z

TTL input signal by encoder or encoder simulation

7

Z

8

The function of this cable has to be set in the basic device:

z

S

z

Lc

z

E

z

Sense (sensor lead for voltage regulation, Lenze setting)

z

Lamp control

z

Enable

SUBD09010

9

B

TTL input signal by encoder or encoder simulation

X10

Pin

Designation

Explanation

1

6

5

9

1

B

TTL output signal from encoder or encoder simulation

2

A

3

A

4

+5 V

V

CC

±6 %

5

GND

-

6

Z

TTL output signal from encoder or encoder simulation

7

Z

8

Enable

Digital output signal

SUBD09010

9

B

TTL output signal from encoder or encoder simulation