Accessories (overview) – Lenze 9400 Manual User Manual
Page 486
Advertising
Accessories (overview)
Components for operation in the DC-bus connection
DC-feeding point
9
486
EDS94SPP101 EN 7.1
Electrical installation
max. 100 A
max. 50 mm² (AWG 1)
+Ug
+Ug
-Ug
-Ug
+Ug
-Ug
E94AZEX100
+
+
-
-
X109
X110
E94AZEX006
Terminal
X119/X120/X12
9/X130
Labelling
Description
*/-
Threaded bolt for connecting the input and output cables (+UG, -UG) with
M8 ring cable lug
E94AZEX007
Terminal data
Max. conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
E94AZEX100
50
1
7
62
SW13
Terminal
X109/X110
Labelling
Description
*/-
Busbar connection (+UG, -UG)
E94AZEX008
Terminal data
Max. conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
E94AZEX100
–
–
3.2 ... 3.5
28 ... 31
PH2
Advertising