Regenerative power supply modules

Device description

7

283

EDS94SPP101-7.1

Standard device

Design

Pos.

Description

VR module

MXI1

Expansion slot 1, e.g. for communication

;

MXI2

Expansion slot 2, e.g. for communication

;

MMI

Storage module slot

;

MSI

Reserved

†

X1

System bus (CAN), under the cover

;

X2

24 V supply and statebus

;

X3

Analog inputs and analog outputs

2/2

X4

Digital outputs

4

X5

Digital inputs

8

X6

Diagnostics

;

X7

Reserved (resolver)

†

X8

Control signals for mains filter (encoder)

;

Lower cover

;

Retractable nameplate

;

Upper cover

;

Prominent warning label close to the device!

;

The LED display enables fast indication of several operating states.

LED

Labelling

Colour

Description

CAN-RUN

green

CAN bus ok

CAN-ERR

red

CAN bus error

DRIVE READY

green

Standard device is ready for operation

DRIVE ERROR

red

Error in the standard device or application-induced

24 V

green

24 V supply voltage ok

SSP94LED01

USER

yellow

Message parameterised by the application

Pos.

Symbol

Description

Long discharge time: All power terminals carry hazardous voltages for at

least 3 minutes after mains disconnection!

High discharge current: Fixed installation and PE connection to EN 61800-5-1

required!

Electrostatic sensitive devices: Before working on the device, personnel must

ensure that they are free of electrostatic charge!

Installation backplane

Design

Pos.

Description

VR module

X111

Mains supply via mains filter/DC-bus voltage

;

X112

Mains supply and mains power recovery via mains filter/external brake resistor

;

X109

DC busbar +

;

X110

DC busbar -

EMC shield clamp

;