Accessories (overview) – Lenze 9400 Manual User Manual
Page 440
Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHN0025
9
440
EDS94SPP101 EN 7.1
Elements of the motor brake control
Pos.
Description
Nameplate
X117
Control connection
X107
Connection of supply and brake
Standards
Conformity and approval
Conformity
CE
2006/95/EC
Low-Voltage Directive
Approval
UR
UL 508C
Industrial Control Equipment Recognised
(file no. E132659) for USA
Protection of persons and equipment
Enclosure
EN 60529
IP00
Protective measures
Against short circuit
Mounting conditions
Mounting place
In the control cabinet
Mounting position
Vertically
Mounting clearances
Above/below
≥
25 mm
To the sides
Side-by-side mounting without clearance
EMC
Noise emission
EN 61800-3
Conducted, category C2.
Noise immunity
EN 61800-3
Burst on mains cable:
2 kV/5 kHz
Burst on control cable:
2 kV/5 kHz
Surge on mains cable:
1 kV (1.2 μs/50 μs;
phase - phase)
2 kV (1.2 μs/50 μs; phase - PE)
Operating conditions
The operating conditions correspond to the operating conditions for the standard device
to which the DC-feeding point is connected.