Single-axis controllers – Lenze 9400 Manual User Manual

Page 123

Advertising
background image

Single-axis controllers

Wiring

Devices in the range 145 ... 695 A (75 ... 370 kW)

4

123

EDS94SPP101 EN 7.1

Operation with DC supply
ForoperationwithDCsupply, theinternal fansmust beconnected viathe internalterminal

FK103 to the 400/500 V AC mains voltage.
When opening the upper housing cover, you will find the pluggable terminal FK103 at the

top in the device on the switched-mode power supply card.

94SSPGG852

Interface card

Switched-mode power supply card

FK103

Fan voltage terminal

Remove the cable bridges of the terminal. Then, connect the mains voltage to

FK103.101/100.

FK103

Labelling

Description

101103 NC NC 100102

101

Fan L1

by default bridged

103

Mains phase

(internal)

NC

not assigned

NC
100

Fan L2

by default bridged

SSP94FK103

102

Mains phase

(internal)

Terminal data

Max. conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

2.5

12

0.5 ... 0.6

4.5 ... 6.2

Slot

0.6 x 3.5

With wire end

ferrule

Rated values - internal fan, AC 400 V
Gg

Type

I [A]

P [W]

8S

E94ASxE1454

0.3

120

8

E94ASxE1724

E94ASxE2024

1.2

480

9

E94ASxE2454

E94ASxE2924

E94ASxE3664

1.2

480

10

E94ASxE4604

1.2

480

E94ASxE5724

E94ASxE6354

E94ASxE6954

2.8

1120

Advertising