10 memory modules, Regenerative power supply modules – Lenze 9400 Manual User Manual

Page 306

Advertising
background image

Regenerative power supply modules

Wiring

Memory modules

7

306

EDS94SPP101-7.1

7.6.10

Memory modules

Use these modules in slot † MXI1 †MXI2 ;MMI †MSI.

MM220
Equipment MM220:

ƒ

1 MB flash memory

ƒ

System bus address switch (CAN)

SSP94M1001

Fig. 7-10

Memory module with DIP switch (as of order designation E94AYM22)

Baud

CAN Address

O

N

c

d

b

a

64

32

16

8

4

2

1

A

9400CAN003

Fig. 7-11

Arrangement and labelling of the DIP switches

For the DIP switches that are placed at the front

ƒ

the node address (labelling ”1” ... ”64”) and

ƒ

baud rate (labelling ”a” ... ”d”)

can be set.

Note!

If all address switches adopt the ”OFF” position when the basic device is

switched on, the configurations of codes C00350 (nodes address) and C00351

(baud rate) apply.
Switch the voltage supply of the basic device off and then on again to activate

altered settings.

Setting the node address
The node address of the drive is calculated from the sum of all address switches in the ”ON”

position.