Accessories (overview), Rated data – Lenze 9400 Manual User Manual

Page 431

Advertising
background image

Accessories (overview)

Motor holding brake control modules

Motor holding brake control module E94AZHY0101

9

431

EDS94SPP101 EN 7.1

Rated data

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94AZHY0101

24

0 (DC)

0.3 ... 5

0.3 ... 5

2

c

Temperature in the control cabinet

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94AZHY0101

24

0 (DC)

0.3 ... 5

0.3 ... 5

2

c

Temperature in the control cabinet

Area

Values

Input voltage

DC 24 V (18 ... 30 V)

Output voltage

Corresponds to input voltage

Brake current

0.3 ... 5 A

Switching capacity

Max. 110 W

Breaking energy

Max. 10 Ws

Cable protection

Recommendation: 7.5 A, tripping characteristic ”B” or ”C”

Control input

Control voltage

Internal

Control current
Protective function

Maximum cable length

In the chapter ”Electrical installation” the dependency of the cable length on

the brake current and the cable cross-section is described.

Operating frequency

Max. 6/min

Operating times

Can be ignored compared to the delay time of the brake.

See documentation of the brake.

Service life

> 10 millions of cycles

Protection against

Overload

No

Short circuit of the

terminals

Yes

Polarity reversal at the

input

Yes

Insulation

1)

Double insulation (EN61800-5-1: V

rated

= 300 V AC),

Separation (UL: V

rated

= 500 V AC)

1)

Brake connection against control card of the controller