Accessories (overview)

Motor holding brake control modules

Motor holding brake control module E94AZHY0025

9

451

EDS94SPP101 EN 7.1

Installation steps
1. Plug the motor brake control module onto the terminals  of the standard device.

– Ensure that both clips  snap into the slots  of the standard device!

2. Check that the motor brake control module is securely connected.

Terminal data

Terminal X107

Labelling

Description
Connection of the motor holding brake:

BD1

BD2

+ (Lenze: WH)

- (Lenze: BN)

E94AZHY0025: 205 V DC, max. 0.75 A

Ensure correct polarity!

SSP94A6107

L1

L2/N

Supply voltage of the motor holding brake

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

0.5 ... 2.5

20 ... 12

Spring terminal

With wire end

ferrule

Stripping length or contact length: 8 mm

Connection plan

L1
L2
L3

N

PE

F10

BD1

BD1

L1

L3

PE

L2

L1

L3

PE

L2

BD2

BD2

M

3~

M

3~

£ 2.5 mm²

E94APNExxx4

E94ASxExxx4

E94AMxExxx4

E94AZHY0025

E94AZHY0025

L1

L2/N

L2/N L1

"

"

"

"

X107

X107

E94AZH016

F10

Observe the cable protection standards for fuse dimensioning!

HF shield termination through large-surface PE connection

Advertising