Accessories (overview)

Communication modules

DeviceNet

9

375

EDS94SPP101 EN 7.1

Terminal data

E94YCDN001C

The bus of the communication module is connected via the 5-pole plug connector with

double screw connection (X225).

Designation

Cable colour

Description

V+

red

External voltage supply

z

U = 24 V DC

z

I

max

= 170 mA

CAN_H

white

Data line / input for bus terminating resistor (120 Ω)

SHIELD

Shielding

CAN_L

blue

Data line / input for bus terminating resistor (120 Ω)

V-

black

Reference potential for external voltage supply

Type

Values

Electrical connection

Plug connector with double screw connection

Possible connections

rigid:

2.5 mm

2

(AWG 14)

flexible:

without wire end ferrule

2.5 mm

2

(AWG 14)

with wire end ferrule, without plastic sleeve

2.5 mm

2

(AWG 14)

with wire end ferrule, with plastic sleeve

2.5 mm

2

(AWG 14)

Starting torque

0.5 ... 0.6 Nm (4.4 ... 5.3 lb-in)

Stripping length

7 mm

External voltage supply

Note!

The communication module must be supplied externally via the DeviceNet

cable!