Accessories (overview)
Communication modules
DeviceNet
9
375
EDS94SPP101 EN 7.1
Terminal data
E94YCDN001C
The bus of the communication module is connected via the 5-pole plug connector with
double screw connection (X225).
Designation
Cable colour
Description
V+
red
External voltage supply
z
U = 24 V DC
z
I
max
= 170 mA
CAN_H
white
Data line / input for bus terminating resistor (120 Ω)
SHIELD
Shielding
CAN_L
blue
Data line / input for bus terminating resistor (120 Ω)
V-
black
Reference potential for external voltage supply
Type
Values
Electrical connection
Plug connector with double screw connection
Possible connections
rigid:
2.5 mm
2
(AWG 14)
flexible:
without wire end ferrule
2.5 mm
2
(AWG 14)
with wire end ferrule, without plastic sleeve
2.5 mm
2
(AWG 14)
with wire end ferrule, with plastic sleeve
2.5 mm
2
(AWG 14)
Starting torque
0.5 ... 0.6 Nm (4.4 ... 5.3 lb-in)
Stripping length
7 mm
External voltage supply
Note!
The communication module must be supplied externally via the DeviceNet
cable!