Single-axis controllers – Lenze 9400 Manual User Manual

Page 48

Advertising
background image

Single-axis controllers

Rated data (devices for 400/500V mains)

Overview

4

48

EDS94SPP101 EN 7.1

Output data

Voltage

Frequency

1)

Current [A]

Number of

phases

Type

[V]

[Hz]

max. +45 °C

c

max. +55 °C

c

E94ASxE0024

0 - 230/400/500

0 - 480

1.5/1.5/1.3

1.1/1.1/1.0

3

E94ASxE0034

0 - 230/400/500

0 - 480

2.5/2.5/2.2

1.9/1.9/1.7

3

E94ASxE0044

0 - 230/400/500

0 - 480

4/4/3.5

3/3/2.6

3

E94ASxE0074

0 - 230/400/500

0 - 480

7/7/6.1

5.3/5.3/4.6

3

E94ASxE0134

0 - 230/400/500

0 - 480

13/13/11.4

9.8/9.8/8.6

3

E94ASxE0174

0 - 230/400/500

0 - 480

16.5/16.5/14.4

12.4/12.4/10.8

3

E94ASxE0244

0 - 230/400/500

0 - 480

23.5/23.5/20.6

17.6/17.6/15.5

3

E94ASxE0324

0 - 230/400/500

0 - 599

32.0/32.0/28.0

24.0/24.0/21.0

3

E94ASxE0474

0 - 230/400/500

0 - 599

47.0/47.0/41.0

35.3/35.3/30.8

3

E94ASxE0594

0 - 230/400/500

0 - 599

59.0/59.0/51.6

44.3/44.3/38.7

3

E94ASxE0864

0 - 230/400/500

0 - 599

86.0/86.0/75.3

64.5/64.5/56.4

3

E94ASxE1044

0 - 230/400/500

0 - 599

104/104/91.0

78.0/78.0/68.3

3

E94ASxE1454

0 - 400/500

0 - 599

145/145

131/131

3

E94ASxE1724

0 - 400/500

0 - 599

172/172

155/155

3

E94ASxE2024

0 - 400/500

0 - 599

202/202

182/182

3

E94ASxE2454

0 - 400/500

0 - 599

245/245

221/221

3

E94ASxE2924

0 - 400/500

0 - 599

292/292

263/263

3

E94ASxE3664

0 - 400/500

0 - 599

366/366

329/329

3

E94ASxE4604

0 - 400/500

0 - 599

460/460

414/414

3

E94ASxE5724

0 - 400/500

0 - 599

572/572

515/515

3

E94ASxE6354

0 - 400/500

0 - 599

635/635

572/572

3

E94ASxE6954

0 - 400/500

0 - 599

695/695

626/626

3

c

Temperature in the control cabinet

1)

The limitation to 599 Hz does not apply to the ”servo control” modes (see C00006 = 1 or 2). Generally applies: the

output frequency is limited to 1/8 of the selected chopper frequency (see C00018).

Note!

The indicated output voltage will not be reached under certain operating

conditions.

ƒ

Output power in the maximum range

ƒ

High switching frequencies

ƒ

Use of mains filters or mains chokes

ƒ

Mains supply with high impedance (U

k

> 5 %)

Advertising