Power supply modules, Internal brake chopper data – Lenze 9400 Manual User Manual

Page 224

Advertising
background image

Power supply modules

Rated data (devices for 400/500V mains)

Operation at a rated mains voltage of 500 V

6

224

EDS94SPP101 EN 7.1

Output current and output power

100 %

5-s cycle

3-min cycle

Type

I

DC

[A]

P

DC

[kW]

I

DC

[A]

P

DC

[kW]

I

DC

[A]

P

DC

[kW]

E94APNE0104

10

4.5

40

18.0

15

6.8

E94APNE0104

+ E94AZMP0084

10

6.1

40

24.4

15

9.2

E94APNE0364

36

16.3

108

48.9

54

24.5

E94APNE0364

+ E94AZMP0294

36

21.9

108

65.7

54

32.9

E94APNE1004

100

45.2

200

136

150

67.8

E94APNE100

+ E94AZMP0824

100

60.8

200

182

150

91.2

E94APNE2454

245

111

368

333

368

167

E94APNE2454

+ E94AZMP2004

245

149

368

447

368

224

100 %

Permanent rated values

5-s cycle

Cycle for the second-range
(0.5 s overload/4.5 s recovery time with 75 % of the permanent rated value)

3-min cycle

Cycle for the minute-range
(60 s overload/120 s recovery time with 75 % of the permanent rated value)

Internal brake chopper data

R

Bmin

[Ω]

I

BRmax

[A]

P

BRmax

[kW]

I

BRd

[A]

P

Bd

[kW]

t

Z

[s]

t

on

[s]

t

fp

[s]

Type
E94APNE0104

27.0

29.3

23.1

10.6

3.0

4.3

0.5

0.5

E94APNE0364

12.0

65.8

52.0

29.4

10.4

3.0

0.5

0.5

E94APNE1004

5.0

158

125

63.5

20.1

3.6

0.5

0.5

E94APNE2454

2.8

282

223

113

36.0

3.6

0.5

0.5

R

Bmin

Minimum brake resistance, nominal value ±10 %

I

BRmax

Peak current

P

BRmax

Peak braking power

I

BRd

Continuous current RMS - important for the dimensioning of the cables

P

Bd

Continuous braking power

t

Z

Cycle time, periodic load change with running time and recovery time

t

on

Running time

t

Z

- t

on

Recovery time

t

fp

Maximum running time without initial load and compliance with the recovery

time

Advertising