Single-axis controllers – Lenze 9400 Manual User Manual

Page 146

Advertising
background image

Single-axis controllers

Control terminals

4

146

EDS94SPP101 EN 7.1

Digital outputs
The controller features four freely configurable digital outputs.

Electrical data
24O

GO

24 V external voltage source, optional

according to IEC 61131-2

SELV/PELV

Current consumption

Max. 300 mA

DO1

...

DO4

GO

Switching level

according to IEC 61131-2

LOW

0 V ... +5 V

HIGH

+15 V ... +30 V

Output current

Max. 50 mA

Load

> 480 Ω at 24 V

Note!

For stable digital output states, in particular during the starting phase of the

controller, you must use an external 24V supply for the digital outputs.

Note!

Digital inputs and digital outputs have separated reference potentials (GI and

GO). If you interconnect inputs and outputs, the reference potentials are

connected as well by an external bridge.

24 V =

~

+

-

F

1

GND

In

0

DO4

DO3

DO2

DO1

24O

GO

X4

DO4

DO3

DO2

DO1

24O

GO

X4

SSP94X4DO1

Fig. 4-32

Wiring principle

Wiring with a digital input, e.g. a PLC

Digital control (relay, valve, ...) with an external 24-V supply

X4

Terminal for the digital outputs

In

Digital input, e.g. of a control

GND

Earth reference potential

F

Fuse