Power supply modules

Wiring

Terminal assignment

6

249

EDS94SPP101 EN 7.1

6.6.7

Terminal assignment

Tip!

Complete the wiring of the installation backplane before plugging in the

standard device. The upper terminals of the installation backplane cannot be

connected with a plugged-in standard device.

Mains

Terminal X111

(left part)

Labelling

Description

L1

L2

L3

Connection of the mains phases L1, L2, L3

Connection for the supply-side PE conductor with M5 ring cable lug

SSP940X111

Terminal X112

(right part)

Labelling

Description

L1

L2

L3

Alternative connection at the bottom: mains phases L1, L2, L3

Connection for the supply-side PE conductor with M5 ring cable lug

SSP940X112

Terminal data

Max. conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Device sizes 1 + 2:

flexible

with wire end ferrule

2.5

12

0.5 ... 0.6

4.5 ... 6.2

PZ0

Device size 3:

flexible

with/without wire end

ferrule

10/16

6

1.2 ... 1.5

10.6 ... 13.3

PH1