Accessories (overview), Rated data – Lenze 9400 Manual User Manual

Page 454

Advertising
background image

Accessories (overview)

Motor holding brake control modules

Motor holding brake control module E94AZHN0026

9

454

EDS94SPP101 EN 7.1

Environmental conditions
Climate

Storage

IEC/EN 60721-3-1

1K3 (-25 ... +60 °C)

Transport

IEC/EN 60721-3-2

2K3 (-25 ... +70 °C)

Operation

IEC/EN 60721-3-3

3K3 (-10 ... +55 °C)

Site altitude

0 ... 4000 m amsl

1000 ... 4000 m amsl: current derating of 5 %/1000 m

Pollution

EN 61800-5-1

Pollution degree 2

Vibration resistance

(9.81 m/s

2

= 1 g)

Transport

IEC/EN 60721-3-2

2M2

EN 61800-2

2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s

2

200 ... 500 Hz: acceleration resistant up to 15 m/s

2

Operation

Germanischer Lloyd

5 ... 13.2 Hz: amplitude ±1 mm

13.2 ... 100 Hz: acceleration resistant up to 0.7 g

EN 600068-2-6

10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 10 m/s

2

Rated data

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94AZHN0026

400/500

50/60

0.75/0.75

0.61/0.61

1

c

Temperature in the control cabinet

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94AZHN0026

180/225

0 (DC)

0.75/0.75

0.61/0.61

1

c

Temperature in the control cabinet

Area

Values

Input voltage

AC 400 V (320 ... 550 V), 45 ... 65 Hz

Output voltage

DC 180 V

With mains voltage of AC 400 V

Brake current

0.1 ... 0.61 A

Cable protection

Recommendation: 5 A, tripping characteristic ”B” or ”C”

Control input DI

Signalling output DO

Control voltage

DC 24 V, PLC level
HIGH

LOW

DC +15 ... 30 V

DC 0 ... +3 V

Control current

Input 5 ... 10 mA

Output 5 ... 50 mA

Protective function

Protected against polarity reversal up to DC 60 V

Max. connectable cable

cross-section

2.5 mm

2

AWG 12

Maximum cable length

150 m

Advertising