Flux current min/max, 6 manual tuning of the regulators, Using the test generator – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 119

Advertising
background image

DV-300 Adjustable Speed Drives

——— CONVERTER OPERATION ———

5

43

Table 5.3.5.3.1: Tuning resistances of the field current

Switch ohms

168.5 ohm 333.3 ohm 182 ohm 36.4 ohm 845 ohm 1668 ohm

Equivalent

resistance

Nom flux curr

S14-1

S14-2

S14-3

S14-4

S14-5

S14-6

S14-7

S14-8

1.0 A

OFF

OFF

OFF

OFF

OFF

ON

Not used

1688 ohm

2.0 A

OFF

OFF

OFF

OFF

ON

OFF

845 ohm

3.0 A

OFF

OFF

OFF

OFF

ON

ON

560.9 ohm

5.0 A

OFF

ON

OFF

OFF

OFF

OFF

333.3 ohm

9.9 A

ON

OFF

OFF

OFF

OFF

OFF

168.5 ohm

12.9 A

ON

OFF

OFF

OFF

ON

ON

129.6 ohm

14.2 A

OFF

ON

ON

OFF

OFF

OFF

117.7 ohm

17.1 A

OFF

ON

ON

OFF

ON

ON

97.3 ohm

20.0 A

ON

OFF

ON

OFF

OFF

ON

83.1 ohm

24.1 A

ON

ON

ON

OFF

OFF

OFF

69.3 ohm

25.1 A

ON

ON

ON

OFF

OFF

ON

66.5 ohm

DV0032g

Flux current min/max

- Setting in LIMITS / Flux limits menu via the Flux current max and Flux current min parameters as a

percentage of Nom flux curr.

5.3.6 Manual tuning of the regulators

The tuning of the DV-300 converters is factory set to a typical value for the motor size concerned. This nor-

mally ensures satisfactory regulator results. If this setting, however, meets the requirements of the application

concerned, the regulator need not be optimized.
The converter contains the following close-loop control circuits:
- Regulator of the armature current. The auto tuning has to be perform via the R&L Search parameter.
- Speed regulator
- Field current regulator
- Armature voltage regulator

Following is a description of the system suitable to obtain the optimization, if necessary. In order to have a step

function, the internal “Test generator” is used (“SPEC FUNCTIONS” menu). The aim is to obtain a very good

step response.

The analog output can be brought back to the terminal strip, with a sampling time of 2 ms.

using the Test generator

This function generates and makes available some signals with a square wave, with a frequency and a width that

can be set and which can be added to an offset that can be set too. With the parameter Gen access it is possible

to state on which regulator input the signal must be active. Further information can be found in section 6.15.1,

“Test generator”.