2 speed base value, full load current, 3 configuration of the ok relay (terminals 35,36) – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 176

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

48

6.11.2 Speed base value, Full load current

CONFIGURATION

[45]

Speed base value [FF]

[179]

Full load curr [A]

[175]

Max out voltage [V]

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Speed base value [FF]

45

1

16383

1500

1500

-

Full load curr [A]

179

0.1

P465

P465

P465

-

Max out voltage [V]

175

20

999

400

400

-

Speed base value

The Speed base value is defined by the unit specified in the factor function. It is the

reference value for all speed values (reference values, adaptive speed regulation.) given

as a percentage, and corresponds to 100% of the speed. Changing this parameter is only

possible when the drive is disabled (Enable drive = Disabled). The Speed base value

does not define the maximum possible speed, which in some cases can be formed from

the addition of several reference values. This is defined with Speed max amount.

Full load curr

The Full load curr (FLC) parameter is defined in Amps. It corresponds to 100 % of

the current limit. The settings for the current limit and the overload function are based

on this active current value.

Max out voltage

Max armature voltage supplied from the drive. When it has been set as Flux reg mode

“Voltage control”, Max out voltage corresponds to the crossover point. This parameter

has an influence on the intervention threshold of the “Overvoltage” message.

6.11.3 Configuration of the OK relay (Terminals 35,36)

CONFIGURATION

[412]

Ok relay funct

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Ok relay funct

Drive healthy (0)

Ready to Start (1)

412

0

1

0

0

-

Ok relay func

This parameter defines the condition in which the relay contact will close.

Drive healthy

The contact will close when the drive is supplied with voltage

and when there are no failure alarms.

Ready to start

The contact closes when the following conditions are ful-

filled: - The drive has a voltage supply

- There are no failure alarms present

- The drive is enabled with Enable drive.