——— PARAMETER LISTS ———

10

49

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

Input 2 sign

Positive

Negative

390

U16

0

1

1

1

ü

R/W

1

0

-

R/W

1

0

Input 3 sign

Positive

Negative

391

U16

0

1

1

1

ü

R/W

1

0

-

R/W

1

0

Spd threshold

Speed exceeded

Speed not exceeded

393

U16

0

1

-

R

0

1

QD

L

H

R

0

1

Set speed

Speed not ref. val.

Speed = ref. val.

394

U16

0

1

-

R

0

1

QD

L

H

R

0

1

Speed zero thr

Drive not rotating

Drive rotating

395

U16

0

1

-

R

0

1

QD

L

H

R

0

1

Motor pot up

No acceleration

Acceleration

396

U16

0

1

R/W

0

1

ID

L

H

R/W

0

1

Motor pot down

No deceleration

Deceleration

397

U16

0

1

R/W

0

1

ID

L

H

R/W

0

1

Jog +

No jog forwards

Forwards jog

398

U16

0

1

R/W

0

1

ID

L

H

R/W

0

1

Jog -

No backwards jog

Backwards jog

399

U16

0

1

R/W

0

1

ID

L

H

R/W

0

1

Speed sel 0

Value 2

0

not selected

Value 2

0

selected

400

U16

0

1

0

0

-

R/W

0

1

ID

L

H

R/W

0

1

Speed sel 1

Value 2

1

not selected

Value 2

1

selected

401

U16

0

1

0

0

-

R/W

0

1

ID

L

H

R/W

0

1

Speed sel 2

Value 2

2

not selected

Value 2

2

selected

402

U16

0

1

0

0

-

R/W

0

1

ID

L

H

R/W

0

1

Ramp sel 0

Value 2

0

not selected

Value 2

0

selected

403

U16

0

1

-

R/W

0

1

ID

L

H

R/W

0

1

Ramp sel 1

Value 2

1

not selected

Value 2

1

selected

404

U16

0

1

-

R/W

0

1

ID

L

H

R/W

0

1

Overld available

Overload not possible

Overload possible

406

U16

0

1

-

-

-

R

0

1

QD

L

H

R

0

1

Overload state

Current limit value

Current > limit value

407

U16

0

1

-

-

-

R

0

1

QD

L

H

R

0

1

Ser answer delay

408

U16

0

900

0

0

ü

R/W

--

---

Ok relay funct

Drive healthy

Ready to Start

412

I16

0

1

0

0

ü

R/Z

0

1

-

-

Speed fbk sel

Encoder 1

Encoder 2

Tacho

Armature

414

U16

0

3

1

1

ü

R/Z

0

1

2

3

-

R

Encoder 1 pulses

416

Float *

600

9999

1024

1024

ü

R/Z

-