——— PARAMETER LISTS ———

10

2

“Opt2-A/”(Low priority)
“PDC” (High priority)

Parameter available via DGF asynchronous communication

(see the DGF user manual GEI-100339) and/or the Process

Data Channel (PDC).
When using a field bus interface, parameters whose range is

[min=0; max=1] can be assigned to either Virtual digital inputs

(if W access code exists) and/or Virtual digital outputs (if R

access code exists).
The numbers indicate what has to be sent via interface line in

order to set the single parameters.
Letter in brackets in the “Term.” columnAnalog level to be ap-

plied to the terminal in order to start the single function.

IA, QA, ID, QD in the “Term.” column

The function can be accessed via a freely programmable analog

or digital input or output.
IA = analog input
QA = analog output
ID = digital input
QD = digital output.
The eventually present number is the one by which the terminal

is called.

H, L in the “Term.” column

Level of the terminal signals (H=high, L=low) which enables

the single function.

R/W/Z/C

Access possibilities via the serial interface, Bus or Opt2 manual

or asynchronous communication :
R = Read, W = Write, Z = Write only when drive disabled,

C=Command parameter (the writing of any value causes the

execution of a command).

X · Pyy

The value of this parameter can correspond to min/max X times

the value of the yy parameter.

n

ote

!

Parameters name listed in brakets are referred to previous firmware 7.X.

n

ote

!

The parameter number here indicated has to be intended as an offset value, that the user has

always to add to the base value 2000H (= decimal 8192), in order to address parameters when

a serial line/bus or the DGFC card are used. It also possible to accede to the DRIVECOM

parameter with the DRIVECOM standard indexes.