3 speed limitation – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 345

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

217

6.18.3 Speed limitation

DRIVECOM

Speed amount

[1]

Speed min amount [FF]

[2]

Speed max amount [FF]

Speed min/max

[5]

Speed min pos [FF]

[3]

Speed max pos [FF]

[6]

Speed min neg [FF]

[4]

Speed max neg [FF]

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Speed min amount [FF]

1

0

2

32-1

0

0

-

Speed max amount [FF]

2

0

2

32-1

5000

5000

-

Speed min pos [FF]

5

0

2

32-1

0

0

-

Speed max pos [FF]

3

0

2

32-1

5000

5000

-

Speed min neg [FF]

6

0

2

32-1

0

0

-

Speed max neg [FF]

4

0

2

32-1

5000

5000

-

Speed min amount

Defines the minimum speed for both rotation directions (with 6KDV3 ... Q4...).

A lower value than the defined value is not possible, regardless of the reference value

set. It has an effect on the input of the ramp. If the Speed min amount parameter is

changed, the Speed min pos and Speed min neg parameters are set to the same value.

If one of these two parameters is changed later, the last change is valid. The current

value for positive rotation (clockwise) is shown in the display of the keypad. The value

to be entered is based on the factor function.

Speed max amount

Defines the maximum speed for both rotation directions (with 6KDV3 ... Q4...).

The function has an effect on the input of the speed regulator and therefore takes into

account the reference value that comes from the ramp as well as the directly defined

values (see Figure 6.4.2.1). If the Speed max amount is changed, the Speed max pos

and Speed max neg parameters are set to the same value. If one of these two param-

eters is changed later, the last change is valid. The current value for positive rotation

(clockwise) is shown in the display of the keypad. The value to be entered is based on

the factor function.

Speed min pos

Defines the minimum speed for the clockwise rotation of the motor. A lower value than

the defined value is not possible, regardless of the reference value. The function has an

effect on the input of the ramp (see Figure 6.4.1.1). The value to be entered is based on

the factor function.

Speed max pos

Defines the maximum speed for the clockwise rotation of the motor. The function has

an effect on the input of the speed regulator, and therefore takes into consideration the

reference value that comes from the ramp as well as those that are entered directly (see

Figure 6.4.2.1). The value to be entered is based on the factor function.

Advertising