DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

51

Enable fbk bypas

Enable of the automatic change into an armature feedback when the failure message

“Speed fbk loss” is caused by a lack of the encoder or tachometer feedback.

Enabled

Enabled automatic change

Disabled

Disabled automatic change

After an automatic change into an armature feedback, the speed regulator works with the

Speed P bypass and Speed I bypass parameters of the REG PARAMETERS/Percent

values/Speed regulator menu. The failure message “Speed fbk loss” with an enable must

be configured so that it is set as “Activity = Warning”.

Possible working only with constant field current.

Flux weak speed

Speed value as a percentage of Motor max speed, when the Voltage control phase starts.

The Flux weak speed parameter, when the speed feedback control is enabled (Enable

fbk contr = Enabled), is used to underline the fact that during the Voltage control phase

the armature voltage and the feedback signal are not proportional. If the drive works

with a constant torque on the whole regulation range (Flux reg mode = Constant Cur-

rent), it is necessary to insert the factory set 100% value.

Speed fbk error

Max. allowed error expressed as a percentage of the max. output voltage (Max out

voltage). By means of Max out Voltage, Flux weak speed and Motor nominal speed a

relation between motor speed and armature voltage is obtained. If a difference higher

than Speed fbk error occurs a Speed fbk loss failure occours.

Tacho scale

Fine scaling of the speed feedback using a tachometer analog generator (Speed fbk sel

= Tacho). It is a multiplier of the read tach voltage.

For example:

Analog tach = 60V/1000 rpm, motor top running speed 3000 rpm.

Maximum tach volts = (60V/1000 rpm*3000rpm)= 180 VDC.

- Set dip-switch S4 for 181.6V (see table 4.4.3)
- Set the tacho scale parameter = 181.6V / 180V = 1.01
- Fine adjust the value of Tacho scale if the 180 VDC tach voltage is not perfectly reached.

Speed offset

Offset scaling of the feedback circuit.

Encoder 1 pulses

Number of pulses per revolution of the sinusoidal encoder connected to the XE1 connector.

Encoder 2 pulses

Number of pulses per revolution of the digital encoder connected to the XE2 connector.

The Encoder 2 pulses and Motor max speed shall be inside the allowed area shown

in figure 6.11.4.2

100

100

200

300

400

500

600 700 800

900

1000

2000

3000

4000

200

300

400

500

600

700

800

900

1000

2000

3000

4000

5000

6000

10000

Motor max speed vs PPR

Motor

max

speed

Encoder 2 pulses

A

l l

o

w

e

d

a

r e

a

Figure 6.11.4.2: Allowed area for Encoder 2 pulses and Motor max speed

Refresh enc 1

Enable the monitoring of the encoder 1(connector XE1) connection status, in order to