GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 406

Advertising
background image

GEI-100332Ga

——— PARAMETER LISTS ———

10

12

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

FLUX REGULATION (FIELD CURRENT REGULATION) \ Flux \ if curve

I field cnst 40

916

Float

0.0

100.0

40.0

40.0

ü

R/Z

-

I field cnst 70

917

Float

0.0

100.0

70.0

70.0

ü

R/Z

-

I field cnst 90

918

Float

0.0

100.0

90.0

90.0

ü

R/Z

-

Set flux / if

919

U16

0

1

0

0

ü

Z/C

-

Reset flux / if

920

U16

0

1

0

0

ü

Z/C

-

Nom flux curr [A]

(Field curr scale [A])

374

Float

0.5

70.0

S

S

ü

R/Z

-

-

Motor nom flux

(Motor field curr [A])

280

Float

0.00

P374

P374

P374

ü

R/Z

-

-

REG PARAMETERS \ Percent values \ Speed regulator

Speed P [%]

87

Float

0.00

100.00

10.00

10.00

ü

R/W

-

-

Speed I [%]

88

Float

0.00

100.00

1.00

1.00

ü

R/W

-

-

Speed P bypass [%]

459

Float

0.00

100.00

10.00

10.00

ü

R/W

-

-

Speed I bypass [%]

460

Float

0.00

100.00

1.00

1.00

ü

R/W

-

-

REG PARAMETERS \ Percent values \ Flux regulator ( Field regulator)

Flux P [%]

(Fld reg P gain [%])

91

Float

0.00

100.00

2.00

2.00

ü

R/W

-

-

Flux I [%]

(Fld reg I gain [%])

92

Float

0.00

100.00

1.00

1.00

ü

R/W

-

-

REG PARAMETERS \ Percent values \ Voltage reg

Voltage P [%]

493

Float

0.00

100.00

30.00

30.00

ü

R/W

-

-

Voltage I [%]

494

Float

0.00

100.00

40.00

40.00

ü

R/W

-

-

REG PARAMETERS \ Base values \ Speed regulator

Speed P base [A/rpm]

93

Float

000.1

S

0.3 x

P93max

P93max

0.3 x

P93max

P93max

ü

R/Z

-

-

Speed I base [A/rpm·ms]

94

Float

0.001

S

0.3

P94max

0.3

P94max

ü

R/Z

-

-

REG PARAMETERS \ Base values \ Flux regulator (Field regulator)

Flux P base

(Fld reg PG base)

97

Float

1

32767

3277

3277

ü

R/Z

-

-

Flux I base

(Fld reg IG base)

98

Float

1

32767

3277

3277

ü

R/Z

-

-

REG PARAMETERS \ Base values \ Voltage reg

Voltage P base [f%/V]

495

Float

0.0100

S

S

S

ü

R/Z

-

-

Voltage I base [f%/V·ms]

496

Float

0.01

S

S

S

ü

R/Z

-

-

REG PARAMETERS \ In use values

Speed P in use [%]

99

Float

0.00

100.00

S

S

ü

R

-

-

Speed I in use [%]

100

Float

0.00

100.00

S

S

ü

R

-

-

CONFIGURATION

Main commands

Terminals

Digital

252

U16

0

1

Term.(0)

Term.(0)

ü

R/Z

0

1

-

-

Control mode

Local

Bus

253

U16

0

1

Local (0) Local (0)

ü

R/Z

0

1

-

-

Speed base value [FF]

45

U32***

1

16383

1500

1500

ü

R/Z

-

R

Full load curr [A]

179

Float

0.1

P465

P465

P465

ü

R/Z

-

-

Max out voltage [V]

175

Float

20

999

400

400

ü

R/Z

-

-

Ok relay funct

Drive healthy

Ready to Start

412

I16

0

1

0

0

ü

R/Z

0

1

-

-

CONFIGURATION \ Speed fbk

Motor max speed [rpm]

162

Float *

0

6553

1500

1500

ü

R/Z

-

R

Advertising