9 password – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 191

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

63

Ser answer delay

Setting of the minimum delay between the receiving of the last byte from the converter

and the beginning of its answer. This delay avoids conflicts on the serial line, in case

the interface RS485 of the master is not arranged for an automatic commutation Tx/Rx.

The parameter only concerns the working with standard serial line RS485.

e

xamPle

:

if the delay of the commutation Tx/Rx on the master is at its max. 20ms, the setting of the

parameter Ser answer delay should be at a higher numeber of 20ms: 22ms.

Ser protocol sel

Serial protocol signaling procedure.

Ser baudrate sel

Baud rate selection (except for SLINK3)

6.11.9 password

CONFIGURATION

SERVICE

[85]

Pword 1

Password 2

Passwords are used by the operator to protect the parameters from unauthorized accss.

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Pword 1

85

0

99999

0

0

-

Pword 1

Protects the parameters entered by the user from unauthorized changes. It allows the

reset of failure messages (Failure reset) and to change on the keypad the Control

mode even when the bus functioning system has been chosen (Control mode= Bus).

The password can be freely defined by the user in the form of a 5-digit combination.

Proceed as follows to activate Pword 1:
- Select Pword 1 in the CONFIGURATION menu
- This indicates whether the Password is active (Enabled) or not (Disabled)
- If not, press ENTER and enter the password (see Commissioning).
- Press ENTER once more. The keypad indicates that the Password is active (Enabled).
- The password must be saved so that it is valid when the power supply is switched off and then later switched

back on. —> Saving parameters

Proceed as follows to unlock the Pword 1:
- Select Pword in the CONFIGURATION menu
- The display indicates whether the password is active (Enabled) or not (Disabled)
- If yes, press ENTER and enter the password (see start-up)
- Press ENTER again. The display now indicates that the password is not active (Disabled)
- This configuration must be saved in order to keep the password switched off even after the power supply is

turned off and switched back on again. -> Saving parameters

Advertising