GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 315

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

187

Speed demand En

Speed reference calculation enabled.

Winder side

Selection of the winding/unwinding side: 0 = up, 1 = down

W gain

Setting of the speed reference gain used to saturate the loop. Parameter as a percentage

of the increasing/decreasing value of the angular speed reference.

Speed match

Command of the coil “launching” phase for an automatic switching.

Spd match gain

Setting of the speed reference gain during the launching phase, 100% corresponds to a

peripheral speed equal to the line speed.

Spd match acc

Motor acceleration time during the launching phase, in [s].

Spd match dec

Motor deceleration time in [s] if during the launching phase a stop command is given.

Spd match compl

Indication of a completed launching ramp, if it is programmed on a digital output it can

be used to state that the coil can be changed.

Spd match torque

Setting of the torque current during the launching and change phase. The parameter is

given as a percentage of the drive rated current.

W offset

Offset setting on the speed reference for the initial phase of the winder/unwinder when

the line is stopped. The parameter is given in [rpm].

Offset acc time

Setting of the ramp for the initial phase when the machine is stopped. The parameter is

given in [s]. It refers to Speed base value.

W target

Parameter number where the speed reference has to be addressed to. In order to obtain

the real number to be set, it is necessary to add +2000H (8192 decimal) to the parameter

number.

1.

Addressing example on the speed reference 2:

OPTION Menu

————> Torque winder

————> Speed demand

————> W target = 8235

Paragraph 10.4. “List of the high priority parameters’ shows that Speed ref 2 has the

decimal number 43. In order to obtain the value to be entered, it is necessary to add

8192 decimal (fixed offset): 8192 + 427 = 8235

W reference

Monitor for the speed reference.

Jog TW enable

Jog function enabled.

Jog TW speed

Reference setting for Jog function. The parameter is given as a % of Line speed.

Advertising