Analog inputs

For programmable analog inputs see chapter 6.12.2 for more details.

Self tuning of current regulator

See chapter 5.3.5.1.

R&L Search

Command for current regulator self tuning execution

- Enable the drive (Enable Drive parameter= Enabled)
- Start the drive (Start/Stop parameter = Start).

Self tuning of speed regulator

(see chapter 5.3.5.2 for more details):

Fwd-Rev spd tune

Direction of motor shaft rotation for the speed self tune test (Forward or Reverse; For-

ward is clock-wise as seen from shaft drive end).

Test T curr lim

Torque current limit applied during Speed self tune test.

Start

Speed regulator self tuning start command.

Inertia

Total Inertia value at the motor shaft in Kg*m

2

(1 Kg*m

2

= 23.76 lb*ft

2

).

Inertia Nw

New total Inertia value at the motor shaft in Kg*m

2

identified during the speed self tune

procedure. (1 Kg*m

2

= 23.76 lb*ft

2

)

Friction

Friction value (or Loss compensation) in N*m (1 N*m = 0.738 lb*ft).

Friction Nw

New Friction value (or Loss compensation) in N*m identified during the speed self tune

procedure. (1 N*m = 0.738 lb*ft)

Speed P

Proportional coefficient of the speed regulator in percentage

Speed P Nw

New value of Proportional coefficient of the speed regulator in percentage computed

during the speed self tune procedure.

Speed I

Integral coefficient of the speed regulator in percentage

Speed I Nw

New value of Integral coefficient of the speed regulator in percentage computed during

the speed self tune procedure.

Take val

Acquire the parameters after the self tune procedure (overwrite current values).


n

ote

!

This is not a permanent save. Go to “Save parameters” command.