3 failure register – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 257

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

129

6.15.3 Failure Register

SPEC FUNCTIONS

[330]

Failure register

[262]

Failure reset

[263]

Failure reg del

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Failure register

330

1

10

10

10

-

Failure reset

262

-

Failure reg del

263

-

Failure register

The Failure register contains the last 10 failures that have occurred. It also contains

information about the time the failure occurred, based on the operating hours (Life

time), as well as information on the type of failure. This information can be accessed by

pressing the ENTER key on the keypad when a failure is indicated. If several failures

occur in sequence, all the failures are stored in the failure register until a failure occurs

that causes the disconnection of the drive (Latch = ON, see Programmable alarms).The

content of the failure register can also be read out via the bus or the serial interface.

Failure reset

Acknowledgement of a failure. The failure reset can be initiated by pressing the CAN-

CEL key when the failure is shown in the display of the keypad. If, however, several

failures occur in sequence, these can only be reset by selecting Failure reset command

through the ENT key.

Failure reg del

Clearing the failure register.

The informations about the last 10 failures that have occorred are available thru serial line in the following way:
- Set the parameter FAILURE REGISTER [330], it indicates the position number of the failure occurred:
Example, if set to 10 it will be the last failure.
- Read: FAILURE TEXT [327], FAILURE HOUR [328], FAILURE MIN [329], they indicate the type and when

the alarm is occurred