GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 205

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

77

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Digital input 1

137

0

87

OFF (0)

OFF (0)

Inversion in 1

Enabled (1)

Disabled (0)

1267

0

1

Disabled (0)

Disabled (0)

Digital input 2

146

0

87

OFF (0)

OFF (0)

Inversion in 2

Enabled (1)

Disabled (0)

1268

0

1

Disabled (0)

Disabled (0)

Digital input 3

147

0

87

OFF (0)

OFF (0)

Inversion in 3

Enabled (1)

Disabled (0)

1269

0

1

Disabled (0)

Disabled (0)

Inversion in 4

Enabled (1)

Disabled (0)

1270

0

1

Disabled (0)

Disabled (0)

Digital in 5

149

0

87

OFF (0)

OFF (0)

Inversion in 5

Enabled (1)

Disabled (0)

1271

0

1

Disabled (0)

Disabled (0)

Digital in 6

150

0

87

OFF (0)

OFF (0)

Inversion in 6

Enabled (1)

Disabled (0)

1272

0

1

Disabled (0)

Disabled (0)

Digital in 7

151

0

87

OFF (0)

OFF (0)

Inversion in 7

Enabled (1)

Disabled (0)

1273

0

1

Disabled (0)

Disabled (0)

Digital in 8

152

0

87

OFF (0)

OFF (0)

Inversion in 8

Enabled (1)

Disabled (0)

1274

0

1

Disabled (0)

Disabled (0)

Digital input XX

Selection of the parameter that is addressed by the digital input concerned. The follow-

ing assignments are possible:

OFF

Motor pot reset

Motor pot up

Motor pot down

Motor pot sign +

Motor pot sign -

Jog +

Jog -

Failure reset

Torque reduct

Ramp out = 0

Ramp in = 0

Freeze ramp

Lock speed reg

Lock speed I

Auto capture

Input 1 sign +

1)

Input 1 sign -

1)

Input 2 sign +

1)

Input 2 sign -

1)

Input 3 sign +

1)

Input 3 sign -

1)

Zero torque

Speed sel 0

2)

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

Speed sel 1

2)

Speed sel 2

2)

Ramp sel 0

3)

Ramp sel 1

3)

Field loss

Enable flux reg

Enable flux weak

Pad A bit 0

Pad A bit 1

Pad A bit 2

Pad A bit 3

Pad A bit 4

Pad A bit 5

Pad A bit 6

Pad A bit 7

Forward sign

Reverse sign

An in 1 target

An in 2 target

An in 3 target

Enable droop

Enable PI PID

4)

Enable PD PID

4)

PI integral freeze

4)

24

25

26

27

29

30

31

32

33

34

35

36

37

38

39

44

45

46

47

48

49

52

53

54

PID offs. Sel

4)

PI central vs0

4)

PI central vs1

4)

Diameter calc

4)

Diam reset

Diam calc Dis

Torque winder EN

Line acc status

Line dec status

Line fstp status

Speed match

Diam inc/dec En

Wind/unwind

Diam preset sel0

Diam preset sel1

Taper enable

Speed demand En

Winder side

Enable PI-PD PID

Jog TW enable

Brake fbk

5)

Adapt Sel 1

6)

Adapt Sel 2

7)

55

56

57

58

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

86

87

Advertising