Figure 6.16.3.9: nip-rolls control with load cell – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 285

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

157

Nip-rolls control with load cell

M

M

E

E

0....+10V

+10V

-10V

Feed-forward

Feed-back

-10V

Set

Load cell

Reverse

Forward

Tension set

Forward

Reverse

Line speed
reference

(Internal ramp
master drive)

DRIVE

DRIVE

Line speed

Master

Nip-roll

Figure 6.16.3.9: Nip-rolls control with load cell

Machine data:

Rated speed of slave motor Vn = 3000rpm
Slave motors speed corresponding to the max. line speed = 85% Vn = 2550rpm
Max. correction of the dancer = +/- 20% of the line speed = +/-510rpm

To the slave drive must be sent the analog signals regarding the line speed and the position of the load cell

signal (0... +10V) and the tension set (0... +10V), and the digital commands regarding the enabling of the PID

control.
The regulator output will be sent to the speed reference 1.

Drive setting: (below are parameters regarding only the PID function)

Advertising