4 acceleration / deceleration – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 346

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

218

Speed min neg

Defines the minimum speed for the anti-clockwise rotation of the motor (with 6KDV3...

Q4...). A lower value than the defined value is not possible, regardless of the reference

value. The function has an effect on the input of the ramp (see Figure 6.4.1.1). The value

to be entered is based on the factor function.

Speed max neg

Defines the maximum speed for the anti-clockwise rotation of the motor (with 6KDV3...

Q4...). The function has an effect on the input of the speed regulator, and therefore takes

into consideration the reference value that comes from the ramp as well as the those that

are entered directly (see Figure 6.4.2.1). The value to be entered is based on the factor

function.

6.18.4 Acceleration / Deceleration

DRIVECOM

Acceleration

[21]

Acc delta speed [FF]

[22]

Acc delta time [s]

Deceleration

[29]

Dec delta speed [FF]

[30]

Dec delta time [s]

Quick stop

[37]

QStp delta speed [FF]

[38]

QStp delta time [s]

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Acc delta speed [FF]

21

0

232-1

100

100

Acc delta time [s]

22

0

65535

1

1

Dec delta speed [FF]

29

0

232-1

100

100

Dec delta time [s]

30

0

65535

1

1

QStp delta speed [FF]

37

0

232-1

1000

1000

QStp delta time [s]

38

0

65535

1

1

Quick stop

Quick stop (0)

No Quick stop (1)

343

0

1

No Quick stop

No Quick stop

Acc delta speed

Has the same unit as the ramp reference value and is based on the factor function.

Acc delta time

Is defined in seconds. The ramp output follows the reference value directly if “0 s” is

entered.

Dec delta speed

Has the same unit as the ramp reference value and is based on the factor function.

Dec delta time

Is defined in seconds. If “0 s” is entered, the ramp output follows the reference value

directly.

Qstp delta speed

Has the same unit as the ramp reference value and is based on the factor function.