DV-300 Adjustable Speed Drives

——— PARAMETER LISTS ———

10

17

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

CONFIGURATION \ Prog alarms \ Bus loss

Activity

Ignore

Warning

Disable drive

Quick stop

Normal stop

Curr lim stop

634

U16

0

5

Disable

drive

Disable

drive

ü

R/Z

0

1

2

3

4

5

-

-

Latch

ON

OFF

633

U16

0

1

ON

ON

ü

R/Z

1

0

-

-

Ok relay open

ON

OFF

635

I16

0

1

ON

ON

ü

R/W

1

0

-

-

Hold off time [ms]

636

U16

0

10000

0

0

ü

R/W

-

-

Restart time [ms]

637

U16

0

10000

0

0

ü

R/W

-

-

CONFIGURATION \ Prog alarms \ Hw opt1 failure

Activity

Warning

Disable drive

Quick stop

Normal stop

Curr lim stop

386

U16

1

5

Disable

drive

Disable

drive

ü

R/Z

1

2

3

4

5

-

-

Ok relay open

ON

OFF

387

I16

0

1

ON

ON

ü

R/W

1

0

-

-

CONFIGURATION \ Prog alarms \ Enable seq err

Activity

Ignore

Disable drive

728

U16

0

2

Disable

drive

Disable

drive

ü

R/Z

0

2

-

-

Latch

ON

OFF

729

U16

0

1

ON

ON

ü

R/Z

1

0

-

-

Ok relay open

ON

OFF

730

U16

0

1

ON

ON

ü

R/W

1

0

-

-

CONFIGURATION \ Set serial comm

Device address

319

U16

0

127

0

0

ü

R/Z

-

-

Ser answer delay

408

U16

0

900

0

0

ü

R/W

--

---

Ser protocol sel

SLINK3

MODBUS RTU

JBUS

323

U16

0

2

SLINK3

(0)

SLINK3

(0)

ü

R/W

0

1

2

--

---

Ser baudrate sel

19200

9600

4800

2400

1200

326

U16

0

4

9600

(1)

9600

(1)

ü

R/W

0

1

2

3

4

--

---

CONFIGURATION

Pword 1

85

I32

0

99999

0

0

ü

W

-

-