GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 306

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

178

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Roll diameter [m]

1154

0.000

32.000

****

Line speed [%]

1160

0.00

200.00

Ref line speed [%]

1286

0.00

200.00

Diam calc Dis

ON (1) / OFF (0)

1161

0

1

ON (1)

ON (1)

*

Diam inc/dec En

Enabled (1) / Disabled (0)

1205

0

1

Enabled (0)

Enabled (0)

*

Wind/unwind

Unwinder (1) / Winder (0)

1187

0

1

Winder (0)

Winder (0)

*

Minimum diameter [mm]

799

1

2000

100

100

Maximum diameter [m]

1153

0.000

32.000

1.000

1.000

Line spd source

1204

0

65535

0

0

Ref spd source

1284

0

65535

0

0

Line speed gain

1156

0

32767

0

0

Ref speed gain

1285

0

32767

0

0

Base omega [rpm]

1163

0

8191

1500

1500

Ref speed thr [%]

1155

0

150.00

5

5

Diam filter [ms]

1162

0

5000

100

100

Diam init filter [ms]

1206

0

5000

100

100

Diam stdy delay [ms]

1207

0

60000

0

0

Diam reset

1157

0

1

0

0

*

Diam thr [%]

1158

0

150.00

10

10

Diam reached

1159

0

1

**

Diam preset sel

1168

0

3

0

0

*

Diam preset 0 [m]

1164

0.000

32.000

0

0

Diam preset 1 [m]

1165

0.000

32.000

0

0

Diam preset 2 [m]

1166

0.000

32.000

0

0

Diam preset 3 [m]

1167

0.000

32.000

0

0

***

* This parameter can be set on a programmable digital input.
** This parameter can be set on a programmable digital output.
*** This parameter can be set on a programmable analog input.
**** This parameter can be set on a programmable analog output.

The inputs received by the diameter calculator are the angular speed of the controlled motor and the line speed.

The latter can be measured through an analog input or an encoder.
The value of the calculated diameter can be sent to an analog output; via a digital output it is also possible to

state the overcoming of a programmable threshold.
It is possible to select four values of the starting diameters; one value can derive from an analog input.

Roll diameter

Monitor of the calculated diameter in [m].

Line speed

Monitor of the line speed in [%].

Ref line speed

Reference monitor for the line speed in [%].

Diam calc Dis

Disabling of the diameter calculation (see also par. Ref speed thr). In case such func-

tion is temporarily disabled during the functioning period, the system stores the last

calculated value.

Diam inc/dec En

If enabled and if winder, the calculated diameter can never decrease; if unwinder the

calculated diameter can never increase. It is used to improve the system stability.

Wind/unwind

Winder/unwinder selection. If the selection is carried out via a digital input: 0V = winder,

+24V = unwinder.

Advertising